HVAC Assembly & Test Station

Applicable Products
Automotive HVAC Assembly End-of-Line (EOL) Performance Testing; compatible with traditional ICE (Internal Combustion Engine) vehicles and NEV (New Energy Vehicle) models.

Core Test Items

  • Air Damper Operation Performance Test: Detection of damper angles in various modes, operating torque, and sealing performance.

  • Cooling / Heating Performance Test: Testing of core performance parameters such as airflow, temperature, and static pressure.

  • Electrical Performance & Communication Test: Compatible with CAN/LIN bus protocols; full functional verification of actuators and sensors.

  • NVH (Noise, Vibration, and Harshness) Test: Detection of abnormal noise and vibration to identify hidden assembly defects.

  • Comprehensive Airtightness Test: Verification of the overall sealing performance of the assembly.

 

Description

This dedicated End-of-Line (EOL) final inspection station is designed for the 100% inspection of all passenger vehicle HVAC assemblies, including front HVAC units, rear HVAC units, and dual-zone HVAC assemblies. It integrates five major test modules: NVH testing, air duct airflow and static pressure, motor performance, electronic control switching of heating/cooling modes, and airtightness/leak testing. The standalone workstation can directly interface with the end of a loop assembly line and is scalable for single-unit or multi-station parallel configurations. Equipped with a Siemens industrial HMI and high-speed PROFINET communication, test data is automatically uploaded to the MES. It is ideally suited for the final 100% inspection process in automotive HVAC component manufacturing plants.

Key Advantages & Highlights

One-Stop Integrated Comprehensive Testing

A single unit performs multi-dimensional testing including NVH, airflow, electronic control, and airtightness, eliminating the need for segmented testing across multiple pieces of equipment.

Quick Vehicle Model Changeover

Built-in vehicle model database. One-click switching of product test programs via HMI, with a changeover time of ≤10 min.

High-Precision Acoustic Acquisition System

Enclosed testing environment within a soundproof booth, accurately capturing fan abnormal noise and gear friction noise.

Vehicle Communication Simulation Unit

Built-in CAN/LIN signal simulators, fully replicating the vehicle HVAC control logic.

Automated Reject Marking & Sorting

Automatically prints defect barcodes for non-conforming products, routes them to the rework station, and binds data to the defect root cause.

Compact Footprint Design

A single workstation occupies only 12 m² (12 sqm). Supports parallel expansion and adapts to compact factory layouts.

 

Core System Specifications Table

Applicable Product

Single-zone / Dual-zone / Integrated Front-and-Rear HVAC Unit Assembly

Test Cycle Time per Unit

90s / unit (Full-item testing)

Control System

Siemens S7-1511C PLC + 15-inch Industrial HMI

Noise Measurement Accuracy

Sound level meter accuracy ±0.5dB, acoustic enclosure background noise ≤ 28dB (A)

Airflow and Static Pressure Range

Airflow 0~1200 m³/h, Static Pressure 0~300 Pa, Accuracy ±1% FS

Communication Interfaces

CAN 2.0B, LIN bus, PROFINET IO

Airtightness Leak Detection Accuracy

Leak rate ≤ 5×10⁻⁴ mbar·L/s

Operating Voltage

AC 380V ±10%, Total Equipment Power 12kW

Data Storage Capacity

Local 500G Industrial PC (IPC), storage capacity for ≥ 10 years of test records

Scalability

Up to 8 test stations in parallel collaboration, unified MES data aggregation

 

Core Functions and Value in Detail

NVH Acoustic Testing Function

Workpieces are automatically fed into a sealed acoustic enclosure. The blower operates at all speed levels to collect noise frequency spectrums. The system automatically compares the data with standard noise curves to identify defects such as abnormal bearing noise, air duct resonance, and gear jamming, thereby eliminating HVAC airflow abnormal noise complaints after vehicle delivery.

Air Duct Airflow and Static Pressure Performance Test

 

Simulates vehicle air intake and recirculation modes. Collects airflow and static pressure data across multiple speed levels to diagnose issues such as duct blockage, poor damper sealing, and insufficient blower power, ensuring uniform distribution of heating and cooling airflow inside the cabin.

 

Electronic Control Mode Switching Test  

Issues commands for heating/cooling, recirculation, and defrost modes via the CAN bus. It tests the response speed and positioning accuracy of damper actuator motors and heating/cooling valves to verify the logic compatibility of the HVAC controller.

 

Assembly Airtightness Leak Detection Function

 

Performs dry leak testing (pressurization) on HVAC housings and heat exchanger pipelines to detect micro-leaks in housing welds and gasket assemblies, preventing refrigerant leakage and cooling/heating performance degradation faults in the vehicle.

 

Digital Quality Traceability Function

Barcode scanning binds the VIN (Vehicle Identification Number) to each HVAC assembly. All test parameters and pass/fail results are synchronously uploaded to the MES system, allowing OEMs to retrieve complete inspection records for individual units at any time, meeting the mandatory quality traceability requirements of IATF16949.

Business Value: Replaces 4-6 manual inspectors; inspection consistency is improved by 90%; human misjudgments are directly eliminated; OEM after-sales complaints regarding HVAC abnormal noise and refrigerant leakage are reduced by 70%; one-stop testing reduces workshop equipment footprint by 30%.

 

Supporting Services & Delivery Assurance

1.Pre-project: Free HVAC process matching assessment, customized noise reduction solutions for acoustic enclosures, and production line interfacing & layout planning;
2.Lead Time: 45 working days for standard standalone units, and 70 working days for multi-station parallel production lines;
3.Implementation: In-house pre-testing with full workpiece samples → Disassembly and shipping → On-site installation of acoustic enclosures, piping, and electrical control joint commissioning → 72-hour continuous trial run verification;
4.Training: Full-process training on equipment operation, fault code interpretation, vehicle model program editing, and MES integration & maintenance;
5.After-sales: 1-year warranty for the entire machine, and a 2-year warranty for acoustic sensors and differential pressure detection modules; 24-hour nationwide on-site maintenance; 1 free equipment precision calibration service per year.